How can we help? +44 (0)1704 543830 | info@isotech.co.uk

Why Isotech Dry Blocks?

-100°C to 1200°C
Calibrate all sensor types

Why Standard Volume?

Gemini / Jupiter / Pegasus
  • Portable and Bench Calibration
  • Range of standard inserts or machined to your specification
  • Accessories for Blackbody and Surface Sensor Calibration

Why Large Volume?

Oceanus / Medusa
  • Deep immersion – up to 300mm
  • Range of standard inserts or machined to your specification
  • Realising Isotech ITS-90 Slim Fixed Point Cells including Water Triple Point, Gallium, Indium, Tim, Zinc and Aluminium

MODELS

Gemini / Jupiter / Pegasus Calibrate all sensor types from 35°C to 1200°C
Jupiter 4852

Jupiter 4852

30°C to 660°C. 35 x 160mm Volume

  • Wide Operating Range to 660°C
  • Fast Response
  • Calibrate Whole Measurement Loop
Product Spec
Gemini 4857

Gemini 4857

High Capacity Blocks to 700°C

  • Calibrate Large Diameter Probes
  • High Capacity Blocks 64 x 160mm
  • Calibrate Whole Measurement Loop
Product Spec
Pegasus 4853

Pegasus 4853

150 °C to 1200°C Portable Calibration Furnace

  • High Temperature Thermocouple Calibration Furnace
  • Custom Furnace Design with Optimised Profile
  • Calibrate Whole Measurement Loop
Product Spec

Options

Basic

Basic
  • The thermometer under test is compared to the dry block controller value
    Useful for moderate temperature ranges and quick testing
  • A control system with digital display shows the set and measured value from the calibration volume
  • Use with a separate external temperature indicator for higher accuracy

Site

Site
  • A thermometer under test is compared to a calibrated standard
  • In addition to the temperature control system with its display the Isotech SITE model includes a separate temperature read out for the Standard (Reference) probe

Advanced

Advanced
  • Isotech Advanced models have inputs for both the test thermometer and a calibrated standard.
  • The Isotech Adavanced models have three input channels so that both the Standard and the Test Probes can be connected to the temperature read out. Additionally the Advanced models feature data logging, Ethernet, greater accuracy and further additional features.

Large Volume Calibrators

Oceanus / Medusa / Medusa 511
Oceanus-6

Oceanus-6

-25°C to 140°C, Large 50 x 300mm Volume

Product Spec
Medusa 510

Medusa 510

Covering 30°C to 550°C, 45 x 285mm Volume

Product Spec
Medusa 511

Medusa 511

Covering 50°C to 700°C, 45 x 285mm Volume