This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
DESCRIPTION
These industrial platinum resistance thermometers (IPRT / PRT) are ideal for field and lab use. Suitable for use as working standards in Dry Blocks and Liquid Baths or as high accuracy probes for our range of True Temperature Indicators.
NEW: We now have 90 degree angled probes to a maximum temperature of 660°C. They are primarily for use in our Portable Temperature Calibrators for applications where the units under test have a terminal head fitted that would otherwise obstruct a longer reference thermometer. These sensors should be calibrated as part of the Portable Calibrator.
All the thermometers are metal sheathed and both less fragile, and more affordable than the Isotech range of true Standard Platinum Resistance Thermometers that are used in laboratories and our found in our publication “Solutions for Primary and Secondary Laboratories”.
All the thermometers use handmade Pt100 coil wound platinum sensing elements (RTD) to give high accuracy and low drift. Isotech’s UKAS accredited lab can calibrate to the smallest of uncertainties.
Calibration should be specified to suit the particular operating range and application. Isotech can advise on which service is appropriate to match the temperature range and application.
SPECIFICATION
Technical Feature | Value |
---|---|
Ro | 100Ω ± 0.05Ω |
Alpha | 0.003850 ± 0.000005 |
Standard | IEC 60751 |
Stability | 0.010Ω/ year |
Recommended Current | 1mA |
Self Heating at 1mA | 0.004°C |
Calibration | Optional UKAS Calibration at extra cost. See table for typical uncertainties. |
Connection | 4 Wire |
Max. Handle Temperature | 80°C |
Model Types
Model | Range | Diameter | Length |
General Purpose | Further Details | ||
935-14-112 | -5o°C to 250°C | 3 mm | 225 mm |
935-14-61 | -5o°C to 250°C | 4 mm | 300 mm |
935-14-13 | -196°C to 250°C | 6 mm | 350 mm |
935-14-113 | -100°C to 250°C | 6 mm | 350 mm |
935-14-16 | -100°C to 450°C | 6 mm | 450 mm |
935-14-116 | -100°C to 450°C | 6 mm | 350 mm |
935-14-72 | -5o°C to 670°C | 6 mm | 375 mm |
935-14-98 | -5o°C to 350°C | 4 mm | 300 mm |
Working Industrial Standards | Further Details | ||
935-14-95L | -200°C to 165°C | 6 mm | 480 mm |
935-14-95H | -8o°C to 670°C | 6 mm | 480 mm |
Angled Probes | Further Details | ||
935-14-82 | -5o°C to 250°C | 4 mm | 165 mm |
935-14-85 | -5o°C to 250°C | 6 mm | 385 mm |
935-14-75 | -5o°C to 250°C | 4 mm | 213 mm |
935-14-79 | 0°C to 660°C | 6 mm | 199 mm |
DOWNLOADS
Semi Standard PRTS
We now have 90 degree angled probes to a maximum temperature of 660°C.
These industrial platinum resistance thermometers are ideal for field and lab use. Suitable for use as working standards in Dry Blocks and Liquid Baths or as high accuracy probes for our range of True Temperature Indicators.
- High Accuracy, -200°C to 660°C
- Working Standards In Dry Blocks and Liquid Baths
- Field and Laboratory Use
We are online and ready to chat to you if you need any advice and support, or if you prefer you can fill out the form below.
Or call +44 01704 543830